Brand We Work With
Products

Fire Alarm Control Panel
We offer the Addressable Fire Alarm Control Panel designed for precise fire detection and reliable system management in large-scale installations.

Multi Detector
Multi Detector provides advanced, multi-criteria fire detection, ensuring accurate and timely responses to potential fire hazards in any environment.

Smoke Detector
Smoke Detector offers reliable early detection of fire by sensing smoke particles, providing a critical first line of defense in fire safety.

Heat Detector
Heat Detector quickly identifies abnormal temperature rises, ensuring early warning in environments where smoke detection may not be effective.

Input Module
Input Module integrates seamlessly with fire alarm systems, enabling reliable monitoring and control of various fire safety devices for enhanced protection.

Output Module
Output Module facilitates the activation of external fire safety devices, such as alarms and sprinklers, ensuring a swift response during fire emergencies.

Isolator
Isolator enhances fire safety system reliability by isolating faulty sections during a fire, preventing system-wide failure and ensuring continued protection.

Horn with Strobe
Horn with Strobe combines loud audible alerts with bright visual signals, ensuring effective fire alarms for both hearing and visually impaired individuals in emergency situations.

Upright Fire Sprinkler
Fire sprinkler is fitted at the end of pipeline to spray water for extinguishing or suppressing the fire. An upright sprinkler is installed at the top with an upper water deflector, so water coming out of the orifice shoots upward.

Pendent Fire Sprinkler
Fire sprinkler is fitted at the end of pipeline to spray water for extinguishing or suppressing the fire. A pendent sprinkler protrudes and hangs down from the ceiling.

Sidewall Fire Sprinkler
Fire sprinkler is fitted at the end of pipeline to spray water for extinguishing or suppressing the fire. A sidewall sprinkler is installed on the wall along or under a beam with only half of a deflector.

Concealed Sprinkler
Concealed sprinkler at standard and quick response is decorative sprinkler featuring a flat cover plate designed to conceal the sprinkler for aesthetical benefit.

Fire Hose Reel
Fire Hose Reels are designed and manufactured in manual versions with LPCB approved compliance of BS EN 671-1:2012 with semi-rigid hose complying with BS EN 694:2014 standards.

Fire Hose Cabinet
Fire Hose cabinets are made with high-quality M.S. Sheet with powder coating. It is used in the Fire Hydrant & Protection system to protect & adopt Hydrant accessories such as Fire Hose, Nozzles, Hose Angle Valves, Hose Rack

Lay Fire Hose
Angle Hose Valve is constructed with brass & hand wheel from Ductile Iron. It is UL listed & manufactured following UL 668 & as per NFPA 13. Angle Hose Valve is mostly used in Fire Protection Service outlet or a hose rack assembly.

Fire Hose Pin Rack is a semi-automatic pin rack which is used with movable pins and an automatic release mechanism that keeps water out of the hose until the last fold is removed.

Gate Valve
Gate valve is bi-directional isolating valves, and it opens by lifting a round or rectangular gate out of the path of water flow. When fully open, gate valve has no obstruction in the flow path, resulting in very low friction loss.

Butterfly Valve
Gate valve is bi-directional isolating valves, and it opens by lifting a round or rectangular gate out of the path of water flow. When fully open, gate valve has no obstruction in the flow path, resulting in very low friction loss.

Check Valve
Check valve, also known as non-return valve, one-way valve, is used to allow water to flow through it in only one direction, and it works automatically without any external control.

Alarm Check Valve
The Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping.

End Suction Electric Motor Driven Fire Pump Set
End-suction pumps are designed so that the incoming water enters the pump horizontally through the end. The water then changes direction and is discharged vertically, perpendicular to the line of suction. End-suction pumps usually feature a volute casing and only one impeller.

End Suction Diesel Engine Driven Fire Pump Set
The Diesel Fire Pump with a centrifugal single-stage end suction design is widely used in firefighting for docks, buildings, oil storage, factories, and farm irrigation. Built on a cast iron base, it complies with GB6245-2006, NFPA20, and other applicable national standards for fire safety.

Multistage FF Jockey Pump Set
The Check Valve (or non-return valve) allows water to flow in one direction only, operating automatically without external control. It is essential in fire systems to maintain pressure using the XBD-CDL vertical multistage pump, which functions as a jockey pump, ensuring pressure is consistent with NFPA20 standards.

Controller For Fire Fighting Pump Set
The devices within a fire pump controller panel perform such functions as receiving signals from alarm devices, such as pressure operated switches, sprinkler alarm valves or remote fire alarm equipment; activating motor control devices to provide electric power to motors driving fire pumps and monitoring the fire pump operation and performance.